Measures non-contact and magnetostrictive principle in a robust profile. It offers an infinite mechanical life as it works without frictio...
Stroke Value | Resolution | Repeatability | Linearity |
---|---|---|---|
Many different models from 0 ... 50 mm to 4250 mm | Analog: 16 bits (Theoretically infinite) Incremental: 1 μm, 5 μm (Value of one phase for four-phase resolution) SSI: 1 μm, 5 μm or 10 μm Start-Stop Pulse: 2800 ms -1 CANopen: 1 μm either da 5 μm | For analog output models: ≤ 0.03% FS For digital output models: ≤ 6μm | Analog output models: ≤ ± 0.02% FS Digital output models: <250 mm ≤ ± 25 μm <750 mm ≤ ± 30 μm <1000 mm ≤ ± 50 μm <2500 mm ≤ ± 80 μm |
Non-contact and magnetostrictive measuring principle; Special design for integration into hydraulic cylinders; infinite mechanical life; Float...
Stroke Value | Resolution | Repeatability | Linearity |
---|---|---|---|
Many different models from 50 mm to 4250 mm | Analog: 16 Bit SSI: 1 μm, 5 μm or 10 μm IO-Link: 1 μm or 5 μm CANopen: 1 μm or 5 μm | Analog output models: 0.03% FS Digital output models: 6 μm | Analog output models: <± 0.02% (min. ± 50 µm) For digital output models: <250 mm <± 25 μm <750 mm <± 30 μm <1000 mm <± 50 μm <2500 mm <± 80 μm 4250 mm ' up to <± 120 μm |