Electromagnetic Flowmeter - Flanged Type Model, It is the product that makes flow measurement by generating magnetic field and producing electrical signal from these magnetic waves. The ability to perform accurate measurements and the absence of the moving parts in the internal flux provides the use in non-corrosive liquids over almost all 5µs / cm conductivity. Instantaneous and Total flow information can be monitored on LCD 3-line display, analog and frequency (pulse) outputs and RS232, RS485 Modbus communication interfaces and PLC and PID. is assembly. Wastewater Facilities, Food Industry, Textile Industry, Heavy Industry, Machinery Industry and Agricultural Irrigation are used by providing a sensitivity of 0.2%. Product CE Declaration and ISO9001 quality certificates are available and are offered with economic pricing and delivery advantages.
- Electromagnetic Flowmeter - Flanged Type Model are products that measure the flow rate by magnetic field formation and generating electrical signals from these magnetic waves.
- Precise measurement and no moving parts inside the body. It can be used in all liquids above 5μs / cm conductivity value.
- You can monitor the instantaneous and total flow rate information on the LCD 3-line display, and transfer to control calls such as PLC and PID with analog and frequency (pulse) outputs and RS232, RS485 Modbus communication interfaces.
- The product is easily and comfortably mounted on the line with flange connection horizontally or vertically.
- Wastewater Facilities, Food Industry, Textile Industry, Heavy Industry, Machinery Industry and Agricultural Irrigation are used with 0.2% precision.
- The product has CE declaration and ISO9001 quality certificates and it is offered for use with economical pricing and the advantages of delivery from stock.
Type | Economic Type Electromagnetic Flowmeter |
---|---|
Housing Materia | Carbon Steel / Stainless Steel 304/316 (ops.) |
Connection Size | DN10-DN3000 |
Measuring Range | speed | 2-40 l/min | 0.2-15m / s max |
Coil Material | 99% copper |
Minimum Conductivity | 5µs/cm |
Rated Pressure | 0.6MPa / 1.0Mpa / 1.6Mpa / 2.5Mpa / 4.0Mpa |
Internal Coating Materia | PTFE / Neopren / Hard Rubber / F46 / PFA / Polyuret |
Electrode Material | SS316L / Hastelloy B / Hastelloy C / Titanium / Tantalum / Platinum |
Flange Type | JIS / ANSI / DIN or Other |
Ambient Temperature | Rubber -25 to +60 °C /Teflon -20 to 150°C |
Accuracy | % 0.5 / ± 0.3% and ± 0.2% ± (ops.) |
Supply | AC85-250V / DC20-36V |
Output | 4-20mA, Pulse, RS485 Modbus (ops) / HART, Profibus (ops) |
Alarm | Blank Pipe, Excitation, Bottom and Upper Limit |